Showing 55–63 of 71 results

  • TSP7-3P
    Read moreLoading Done

    TSP7-3P

    0 out of 5
    • lnnovative tripping and breaking technology.
    • Pluggable design, no need to interrupt the system when being plugged or unplugged.
    • A single module can reach up to 40kA(8/20us).
  • TSPV-25
    Read moreLoading Done

    TSPV-25

    0 out of 5

    Parameters and features
    Standard: IEC60269-1 & IEC60269-6
    Rated voltage: DC1000V
    Rated current: 20A
    Breaking capacity: 33 KA
    Operating class: gPV
    Protection objects: It is used in the photovoltaic combiner box to provide safe and reliable
    protection for overload and short-circuit current faults of PV modules and PV arrays.
    Applicable environment: Temperature, -5°C~+40°C;
    Humidity, less than 90%

  • TSPV-25B
    Read moreLoading Done

    TSPV-25B

    0 out of 5

    Parameters and features
    Standard: IEC60269-1 & IEC60269-6
    Rated voltage: DC1000V
    Rated current: 20A
    Breaking capacity: 33 KA
    Operating class: gPV
    Protection objects: It is used in the photovoltaic combiner box to provide safe and reliable
    protection for overload and short-circuit current faults of PV modules and PV arrays.
    Applicable environment: Temperature, -5°C~+40°C;
    Humidity, less than 90%

  • TSPV-32
    Read moreLoading Done

    TSPV-32

    0 out of 5

    Parameters and features
    Standard: IEC60269-1 & IEC60269-6
    Rated voltage: DC1000V
    Rated current: 20A
    Breaking capacity: 33 KA
    Operating class: gPV
    Protection objects: It is used in the photovoltaic combiner box to provide safe and reliable
    protection for overload and short-circuit current faults of PV modules and PV arrays.
    Applicable environment: Temperature, -5°C~+40°C;
    Humidity, less than 90%

  • TSPV-32B
    Read moreLoading Done

    TSPV-32B

    0 out of 5

    Parameters and features
    Standard: IEC60269-1 & IEC60269-6
    Rated voltage: DC1500V
    Rated current: 32A
    Breaking capacity: 25 KA
    Operating class: gPV
    Protection objects: It is used in the photovoltaic combiner box to provide safe and reliable
    protection for overload and short-circuit current faults of PV modules and PV arrays.
    Applicable environment: Temperature, -5°C~+40°C;

  • TSQ7-125 1P
    Read moreLoading Done

    TSQ7-125 1P

    0 out of 5

    Application
    The changeover switch can switch on, load and break the circuit under the normal conditions,
    using as switch disconnectors

  • TSQ7-125 3PTSQ7-125 3P
    Read moreLoading Done

    TSQ7-125 3P

    0 out of 5

    Application
    The changeover switch can switch on, load and break the circuit under the normal conditions,
    using as switch disconnectors

  • TSQ7-40 1P
    Read moreLoading Done

    TSQ7-40 1P

    0 out of 5

    Application
    The changeover switch can switch on, load and break the circuit under the normal conditions,
    using as switch disconnectors.

  • TSQ7-40 2PTSQ7-40 2P
    Read moreLoading Done

    TSQ7-40 2P

    0 out of 5

    Application
    The changeover switch can switch on, load and break the circuit under the normal conditions,
    using as switch disconnectors.

End of content